As per the RFC, bring in the ORTE async progress code and the rewrite of OOB: *** THIS RFC INCLUDES A MINOR CHANGE TO THE MPI-RTE INTERFACE *** Note: during the course of this work, it was necessary to completely separate the MPI and RTE progress engines. There were multiple places in the MPI layer where ORTE_WAIT_FOR_COMPLETION was being used. A new OMPI_WAIT_FOR_COMPLETION macro was created (defined in ompi/mca/rte/rte.h) that simply cycles across opal_progress until the provided flag becomes false. Places where the MPI layer blocked waiting for RTE to complete an event have been modified to use this macro. *************************************************************************************** I am reissuing this RFC because of the time that has passed since its original release. Since its initial release and review, I have debugged it further to ensure it fully supports tests like loop_spawn. It therefore seems ready for merge back to the trunk. Given its prior review, I have set the timeout for one week. The code is in https://bitbucket.org/rhc/ompi-oob2 WHAT: Rewrite of ORTE OOB WHY: Support asynchronous progress and a host of other features WHEN: Wed, August 21 SYNOPSIS: The current OOB has served us well, but a number of limitations have been identified over the years. Specifically: * it is only progressed when called via opal_progress, which can lead to hangs or recursive calls into libevent (which is not supported by that code) * we've had issues when multiple NICs are available as the code doesn't "shift" messages between transports - thus, all nodes had to be available via the same TCP interface. * the OOB "unloads" incoming opal_buffer_t objects during the transmission, thus preventing use of OBJ_RETAIN in the code when repeatedly sending the same message to multiple recipients * there is no failover mechanism across NICs - if the selected NIC (or its attached switch) fails, we are forced to abort * only one transport (i.e., component) can be "active" The revised OOB resolves these problems: * async progress is used for all application processes, with the progress thread blocking in the event library * each available TCP NIC is supported by its own TCP module. The ability to asynchronously progress each module independently is provided, but not enabled by default (a runtime MCA parameter turns it "on") * multi-address TCP NICs (e.g., a NIC with both an IPv4 and IPv6 address, or with virtual interfaces) are supported - reachability is determined by comparing the contact info for a peer against all addresses within the range covered by the address/mask pairs for the NIC. * a message that arrives on one TCP NIC is automatically shifted to whatever NIC that is connected to the next "hop" if that peer cannot be reached by the incoming NIC. If no TCP module will reach the peer, then the OOB attempts to send the message via all other available components - if none can reach the peer, then an "error" is reported back to the RML, which then calls the errmgr for instructions. * opal_buffer_t now conforms to standard object rules re OBJ_RETAIN as we no longer "unload" the incoming object * NIC failure is reported to the TCP component, which then tries to resend the message across any other available TCP NIC. If that doesn't work, then the message is given back to the OOB base to try using other components. If all that fails, then the error is reported to the RML, which reports to the errmgr for instructions * obviously from the above, multiple OOB components (e.g., TCP and UD) can be active in parallel * the matching code has been moved to the RML (and out of the OOB/TCP component) so it is independent of transport * routing is done by the individual OOB modules (as opposed to the RML). Thus, both routed and non-routed transports can simultaneously be active * all blocking send/recv APIs have been removed. Everything operates asynchronously. KNOWN LIMITATIONS: * although provision is made for component failover as described above, the code for doing so has not been fully implemented yet. At the moment, if all connections for a given peer fail, the errmgr is notified of a "lost connection", which by default results in termination of the job if it was a lifeline * the IPv6 code is present and compiles, but is not complete. Since the current IPv6 support in the OOB doesn't work anyway, I don't consider this a blocker * routing is performed at the individual module level, yet the active routed component is selected on a global basis. We probably should update that to reflect that different transports may need/choose to route in different ways * obviously, not every error path has been tested nor necessarily covered * determining abnormal termination is more challenging than in the old code as we now potentially have multiple ways of connecting to a process. Ideally, we would declare "connection failed" when *all* transports can no longer reach the process, but that requires some additional (possibly complex) code. For now, the code replicates the old behavior only somewhat modified - i.e., if a module sees its connection fail, it checks to see if it is a lifeline. If so, it notifies the errmgr that the lifeline is lost - otherwise, it notifies the errmgr that a non-lifeline connection was lost. * reachability is determined solely on the basis of a shared subnet address/mask - more sophisticated algorithms (e.g., the one used in the tcp btl) are required to handle routing via gateways * the RML needs to assign sequence numbers to each message on a per-peer basis. The receiving RML will then deliver messages in order, thus preventing out-of-order messaging in the case where messages travel across different transports or a message needs to be redirected/resent due to failure of a NIC This commit was SVN r29058.
2013-08-22 20:37:40 +04:00
# -*- text -*-
#
# Copyright (c) 2004-2005 The Trustees of Indiana University and Indiana
# University Research and Technology
# Corporation. All rights reserved.
# Copyright (c) 2004-2005 The University of Tennessee and The University
# of Tennessee Research Foundation. All rights
# reserved.
2015-06-24 06:59:57 +03:00
# Copyright (c) 2004-2005 High Performance Computing Center Stuttgart,
As per the RFC, bring in the ORTE async progress code and the rewrite of OOB: *** THIS RFC INCLUDES A MINOR CHANGE TO THE MPI-RTE INTERFACE *** Note: during the course of this work, it was necessary to completely separate the MPI and RTE progress engines. There were multiple places in the MPI layer where ORTE_WAIT_FOR_COMPLETION was being used. A new OMPI_WAIT_FOR_COMPLETION macro was created (defined in ompi/mca/rte/rte.h) that simply cycles across opal_progress until the provided flag becomes false. Places where the MPI layer blocked waiting for RTE to complete an event have been modified to use this macro. *************************************************************************************** I am reissuing this RFC because of the time that has passed since its original release. Since its initial release and review, I have debugged it further to ensure it fully supports tests like loop_spawn. It therefore seems ready for merge back to the trunk. Given its prior review, I have set the timeout for one week. The code is in https://bitbucket.org/rhc/ompi-oob2 WHAT: Rewrite of ORTE OOB WHY: Support asynchronous progress and a host of other features WHEN: Wed, August 21 SYNOPSIS: The current OOB has served us well, but a number of limitations have been identified over the years. Specifically: * it is only progressed when called via opal_progress, which can lead to hangs or recursive calls into libevent (which is not supported by that code) * we've had issues when multiple NICs are available as the code doesn't "shift" messages between transports - thus, all nodes had to be available via the same TCP interface. * the OOB "unloads" incoming opal_buffer_t objects during the transmission, thus preventing use of OBJ_RETAIN in the code when repeatedly sending the same message to multiple recipients * there is no failover mechanism across NICs - if the selected NIC (or its attached switch) fails, we are forced to abort * only one transport (i.e., component) can be "active" The revised OOB resolves these problems: * async progress is used for all application processes, with the progress thread blocking in the event library * each available TCP NIC is supported by its own TCP module. The ability to asynchronously progress each module independently is provided, but not enabled by default (a runtime MCA parameter turns it "on") * multi-address TCP NICs (e.g., a NIC with both an IPv4 and IPv6 address, or with virtual interfaces) are supported - reachability is determined by comparing the contact info for a peer against all addresses within the range covered by the address/mask pairs for the NIC. * a message that arrives on one TCP NIC is automatically shifted to whatever NIC that is connected to the next "hop" if that peer cannot be reached by the incoming NIC. If no TCP module will reach the peer, then the OOB attempts to send the message via all other available components - if none can reach the peer, then an "error" is reported back to the RML, which then calls the errmgr for instructions. * opal_buffer_t now conforms to standard object rules re OBJ_RETAIN as we no longer "unload" the incoming object * NIC failure is reported to the TCP component, which then tries to resend the message across any other available TCP NIC. If that doesn't work, then the message is given back to the OOB base to try using other components. If all that fails, then the error is reported to the RML, which reports to the errmgr for instructions * obviously from the above, multiple OOB components (e.g., TCP and UD) can be active in parallel * the matching code has been moved to the RML (and out of the OOB/TCP component) so it is independent of transport * routing is done by the individual OOB modules (as opposed to the RML). Thus, both routed and non-routed transports can simultaneously be active * all blocking send/recv APIs have been removed. Everything operates asynchronously. KNOWN LIMITATIONS: * although provision is made for component failover as described above, the code for doing so has not been fully implemented yet. At the moment, if all connections for a given peer fail, the errmgr is notified of a "lost connection", which by default results in termination of the job if it was a lifeline * the IPv6 code is present and compiles, but is not complete. Since the current IPv6 support in the OOB doesn't work anyway, I don't consider this a blocker * routing is performed at the individual module level, yet the active routed component is selected on a global basis. We probably should update that to reflect that different transports may need/choose to route in different ways * obviously, not every error path has been tested nor necessarily covered * determining abnormal termination is more challenging than in the old code as we now potentially have multiple ways of connecting to a process. Ideally, we would declare "connection failed" when *all* transports can no longer reach the process, but that requires some additional (possibly complex) code. For now, the code replicates the old behavior only somewhat modified - i.e., if a module sees its connection fail, it checks to see if it is a lifeline. If so, it notifies the errmgr that the lifeline is lost - otherwise, it notifies the errmgr that a non-lifeline connection was lost. * reachability is determined solely on the basis of a shared subnet address/mask - more sophisticated algorithms (e.g., the one used in the tcp btl) are required to handle routing via gateways * the RML needs to assign sequence numbers to each message on a per-peer basis. The receiving RML will then deliver messages in order, thus preventing out-of-order messaging in the case where messages travel across different transports or a message needs to be redirected/resent due to failure of a NIC This commit was SVN r29058.
2013-08-22 20:37:40 +04:00
# University of Stuttgart. All rights reserved.
# Copyright (c) 2004-2005 The Regents of the University of California.
# All rights reserved.
# Copyright (c) 2014-2017 Intel, Inc. All rights reserved.
# Copyright (c) 2017 IBM Corporation. All rights reserved.
# Copyright (c) 2018 Research Organization for Information Science
# and Technology (RIST). All rights reserved.
As per the RFC, bring in the ORTE async progress code and the rewrite of OOB: *** THIS RFC INCLUDES A MINOR CHANGE TO THE MPI-RTE INTERFACE *** Note: during the course of this work, it was necessary to completely separate the MPI and RTE progress engines. There were multiple places in the MPI layer where ORTE_WAIT_FOR_COMPLETION was being used. A new OMPI_WAIT_FOR_COMPLETION macro was created (defined in ompi/mca/rte/rte.h) that simply cycles across opal_progress until the provided flag becomes false. Places where the MPI layer blocked waiting for RTE to complete an event have been modified to use this macro. *************************************************************************************** I am reissuing this RFC because of the time that has passed since its original release. Since its initial release and review, I have debugged it further to ensure it fully supports tests like loop_spawn. It therefore seems ready for merge back to the trunk. Given its prior review, I have set the timeout for one week. The code is in https://bitbucket.org/rhc/ompi-oob2 WHAT: Rewrite of ORTE OOB WHY: Support asynchronous progress and a host of other features WHEN: Wed, August 21 SYNOPSIS: The current OOB has served us well, but a number of limitations have been identified over the years. Specifically: * it is only progressed when called via opal_progress, which can lead to hangs or recursive calls into libevent (which is not supported by that code) * we've had issues when multiple NICs are available as the code doesn't "shift" messages between transports - thus, all nodes had to be available via the same TCP interface. * the OOB "unloads" incoming opal_buffer_t objects during the transmission, thus preventing use of OBJ_RETAIN in the code when repeatedly sending the same message to multiple recipients * there is no failover mechanism across NICs - if the selected NIC (or its attached switch) fails, we are forced to abort * only one transport (i.e., component) can be "active" The revised OOB resolves these problems: * async progress is used for all application processes, with the progress thread blocking in the event library * each available TCP NIC is supported by its own TCP module. The ability to asynchronously progress each module independently is provided, but not enabled by default (a runtime MCA parameter turns it "on") * multi-address TCP NICs (e.g., a NIC with both an IPv4 and IPv6 address, or with virtual interfaces) are supported - reachability is determined by comparing the contact info for a peer against all addresses within the range covered by the address/mask pairs for the NIC. * a message that arrives on one TCP NIC is automatically shifted to whatever NIC that is connected to the next "hop" if that peer cannot be reached by the incoming NIC. If no TCP module will reach the peer, then the OOB attempts to send the message via all other available components - if none can reach the peer, then an "error" is reported back to the RML, which then calls the errmgr for instructions. * opal_buffer_t now conforms to standard object rules re OBJ_RETAIN as we no longer "unload" the incoming object * NIC failure is reported to the TCP component, which then tries to resend the message across any other available TCP NIC. If that doesn't work, then the message is given back to the OOB base to try using other components. If all that fails, then the error is reported to the RML, which reports to the errmgr for instructions * obviously from the above, multiple OOB components (e.g., TCP and UD) can be active in parallel * the matching code has been moved to the RML (and out of the OOB/TCP component) so it is independent of transport * routing is done by the individual OOB modules (as opposed to the RML). Thus, both routed and non-routed transports can simultaneously be active * all blocking send/recv APIs have been removed. Everything operates asynchronously. KNOWN LIMITATIONS: * although provision is made for component failover as described above, the code for doing so has not been fully implemented yet. At the moment, if all connections for a given peer fail, the errmgr is notified of a "lost connection", which by default results in termination of the job if it was a lifeline * the IPv6 code is present and compiles, but is not complete. Since the current IPv6 support in the OOB doesn't work anyway, I don't consider this a blocker * routing is performed at the individual module level, yet the active routed component is selected on a global basis. We probably should update that to reflect that different transports may need/choose to route in different ways * obviously, not every error path has been tested nor necessarily covered * determining abnormal termination is more challenging than in the old code as we now potentially have multiple ways of connecting to a process. Ideally, we would declare "connection failed" when *all* transports can no longer reach the process, but that requires some additional (possibly complex) code. For now, the code replicates the old behavior only somewhat modified - i.e., if a module sees its connection fail, it checks to see if it is a lifeline. If so, it notifies the errmgr that the lifeline is lost - otherwise, it notifies the errmgr that a non-lifeline connection was lost. * reachability is determined solely on the basis of a shared subnet address/mask - more sophisticated algorithms (e.g., the one used in the tcp btl) are required to handle routing via gateways * the RML needs to assign sequence numbers to each message on a per-peer basis. The receiving RML will then deliver messages in order, thus preventing out-of-order messaging in the case where messages travel across different transports or a message needs to be redirected/resent due to failure of a NIC This commit was SVN r29058.
2013-08-22 20:37:40 +04:00
# $COPYRIGHT$
2015-06-24 06:59:57 +03:00
#
As per the RFC, bring in the ORTE async progress code and the rewrite of OOB: *** THIS RFC INCLUDES A MINOR CHANGE TO THE MPI-RTE INTERFACE *** Note: during the course of this work, it was necessary to completely separate the MPI and RTE progress engines. There were multiple places in the MPI layer where ORTE_WAIT_FOR_COMPLETION was being used. A new OMPI_WAIT_FOR_COMPLETION macro was created (defined in ompi/mca/rte/rte.h) that simply cycles across opal_progress until the provided flag becomes false. Places where the MPI layer blocked waiting for RTE to complete an event have been modified to use this macro. *************************************************************************************** I am reissuing this RFC because of the time that has passed since its original release. Since its initial release and review, I have debugged it further to ensure it fully supports tests like loop_spawn. It therefore seems ready for merge back to the trunk. Given its prior review, I have set the timeout for one week. The code is in https://bitbucket.org/rhc/ompi-oob2 WHAT: Rewrite of ORTE OOB WHY: Support asynchronous progress and a host of other features WHEN: Wed, August 21 SYNOPSIS: The current OOB has served us well, but a number of limitations have been identified over the years. Specifically: * it is only progressed when called via opal_progress, which can lead to hangs or recursive calls into libevent (which is not supported by that code) * we've had issues when multiple NICs are available as the code doesn't "shift" messages between transports - thus, all nodes had to be available via the same TCP interface. * the OOB "unloads" incoming opal_buffer_t objects during the transmission, thus preventing use of OBJ_RETAIN in the code when repeatedly sending the same message to multiple recipients * there is no failover mechanism across NICs - if the selected NIC (or its attached switch) fails, we are forced to abort * only one transport (i.e., component) can be "active" The revised OOB resolves these problems: * async progress is used for all application processes, with the progress thread blocking in the event library * each available TCP NIC is supported by its own TCP module. The ability to asynchronously progress each module independently is provided, but not enabled by default (a runtime MCA parameter turns it "on") * multi-address TCP NICs (e.g., a NIC with both an IPv4 and IPv6 address, or with virtual interfaces) are supported - reachability is determined by comparing the contact info for a peer against all addresses within the range covered by the address/mask pairs for the NIC. * a message that arrives on one TCP NIC is automatically shifted to whatever NIC that is connected to the next "hop" if that peer cannot be reached by the incoming NIC. If no TCP module will reach the peer, then the OOB attempts to send the message via all other available components - if none can reach the peer, then an "error" is reported back to the RML, which then calls the errmgr for instructions. * opal_buffer_t now conforms to standard object rules re OBJ_RETAIN as we no longer "unload" the incoming object * NIC failure is reported to the TCP component, which then tries to resend the message across any other available TCP NIC. If that doesn't work, then the message is given back to the OOB base to try using other components. If all that fails, then the error is reported to the RML, which reports to the errmgr for instructions * obviously from the above, multiple OOB components (e.g., TCP and UD) can be active in parallel * the matching code has been moved to the RML (and out of the OOB/TCP component) so it is independent of transport * routing is done by the individual OOB modules (as opposed to the RML). Thus, both routed and non-routed transports can simultaneously be active * all blocking send/recv APIs have been removed. Everything operates asynchronously. KNOWN LIMITATIONS: * although provision is made for component failover as described above, the code for doing so has not been fully implemented yet. At the moment, if all connections for a given peer fail, the errmgr is notified of a "lost connection", which by default results in termination of the job if it was a lifeline * the IPv6 code is present and compiles, but is not complete. Since the current IPv6 support in the OOB doesn't work anyway, I don't consider this a blocker * routing is performed at the individual module level, yet the active routed component is selected on a global basis. We probably should update that to reflect that different transports may need/choose to route in different ways * obviously, not every error path has been tested nor necessarily covered * determining abnormal termination is more challenging than in the old code as we now potentially have multiple ways of connecting to a process. Ideally, we would declare "connection failed" when *all* transports can no longer reach the process, but that requires some additional (possibly complex) code. For now, the code replicates the old behavior only somewhat modified - i.e., if a module sees its connection fail, it checks to see if it is a lifeline. If so, it notifies the errmgr that the lifeline is lost - otherwise, it notifies the errmgr that a non-lifeline connection was lost. * reachability is determined solely on the basis of a shared subnet address/mask - more sophisticated algorithms (e.g., the one used in the tcp btl) are required to handle routing via gateways * the RML needs to assign sequence numbers to each message on a per-peer basis. The receiving RML will then deliver messages in order, thus preventing out-of-order messaging in the case where messages travel across different transports or a message needs to be redirected/resent due to failure of a NIC This commit was SVN r29058.
2013-08-22 20:37:40 +04:00
# Additional copyrights may follow
2015-06-24 06:59:57 +03:00
#
As per the RFC, bring in the ORTE async progress code and the rewrite of OOB: *** THIS RFC INCLUDES A MINOR CHANGE TO THE MPI-RTE INTERFACE *** Note: during the course of this work, it was necessary to completely separate the MPI and RTE progress engines. There were multiple places in the MPI layer where ORTE_WAIT_FOR_COMPLETION was being used. A new OMPI_WAIT_FOR_COMPLETION macro was created (defined in ompi/mca/rte/rte.h) that simply cycles across opal_progress until the provided flag becomes false. Places where the MPI layer blocked waiting for RTE to complete an event have been modified to use this macro. *************************************************************************************** I am reissuing this RFC because of the time that has passed since its original release. Since its initial release and review, I have debugged it further to ensure it fully supports tests like loop_spawn. It therefore seems ready for merge back to the trunk. Given its prior review, I have set the timeout for one week. The code is in https://bitbucket.org/rhc/ompi-oob2 WHAT: Rewrite of ORTE OOB WHY: Support asynchronous progress and a host of other features WHEN: Wed, August 21 SYNOPSIS: The current OOB has served us well, but a number of limitations have been identified over the years. Specifically: * it is only progressed when called via opal_progress, which can lead to hangs or recursive calls into libevent (which is not supported by that code) * we've had issues when multiple NICs are available as the code doesn't "shift" messages between transports - thus, all nodes had to be available via the same TCP interface. * the OOB "unloads" incoming opal_buffer_t objects during the transmission, thus preventing use of OBJ_RETAIN in the code when repeatedly sending the same message to multiple recipients * there is no failover mechanism across NICs - if the selected NIC (or its attached switch) fails, we are forced to abort * only one transport (i.e., component) can be "active" The revised OOB resolves these problems: * async progress is used for all application processes, with the progress thread blocking in the event library * each available TCP NIC is supported by its own TCP module. The ability to asynchronously progress each module independently is provided, but not enabled by default (a runtime MCA parameter turns it "on") * multi-address TCP NICs (e.g., a NIC with both an IPv4 and IPv6 address, or with virtual interfaces) are supported - reachability is determined by comparing the contact info for a peer against all addresses within the range covered by the address/mask pairs for the NIC. * a message that arrives on one TCP NIC is automatically shifted to whatever NIC that is connected to the next "hop" if that peer cannot be reached by the incoming NIC. If no TCP module will reach the peer, then the OOB attempts to send the message via all other available components - if none can reach the peer, then an "error" is reported back to the RML, which then calls the errmgr for instructions. * opal_buffer_t now conforms to standard object rules re OBJ_RETAIN as we no longer "unload" the incoming object * NIC failure is reported to the TCP component, which then tries to resend the message across any other available TCP NIC. If that doesn't work, then the message is given back to the OOB base to try using other components. If all that fails, then the error is reported to the RML, which reports to the errmgr for instructions * obviously from the above, multiple OOB components (e.g., TCP and UD) can be active in parallel * the matching code has been moved to the RML (and out of the OOB/TCP component) so it is independent of transport * routing is done by the individual OOB modules (as opposed to the RML). Thus, both routed and non-routed transports can simultaneously be active * all blocking send/recv APIs have been removed. Everything operates asynchronously. KNOWN LIMITATIONS: * although provision is made for component failover as described above, the code for doing so has not been fully implemented yet. At the moment, if all connections for a given peer fail, the errmgr is notified of a "lost connection", which by default results in termination of the job if it was a lifeline * the IPv6 code is present and compiles, but is not complete. Since the current IPv6 support in the OOB doesn't work anyway, I don't consider this a blocker * routing is performed at the individual module level, yet the active routed component is selected on a global basis. We probably should update that to reflect that different transports may need/choose to route in different ways * obviously, not every error path has been tested nor necessarily covered * determining abnormal termination is more challenging than in the old code as we now potentially have multiple ways of connecting to a process. Ideally, we would declare "connection failed" when *all* transports can no longer reach the process, but that requires some additional (possibly complex) code. For now, the code replicates the old behavior only somewhat modified - i.e., if a module sees its connection fail, it checks to see if it is a lifeline. If so, it notifies the errmgr that the lifeline is lost - otherwise, it notifies the errmgr that a non-lifeline connection was lost. * reachability is determined solely on the basis of a shared subnet address/mask - more sophisticated algorithms (e.g., the one used in the tcp btl) are required to handle routing via gateways * the RML needs to assign sequence numbers to each message on a per-peer basis. The receiving RML will then deliver messages in order, thus preventing out-of-order messaging in the case where messages travel across different transports or a message needs to be redirected/resent due to failure of a NIC This commit was SVN r29058.
2013-08-22 20:37:40 +04:00
# $HEADER$
#
#
[undeliverable-msg]
An attempt was made to send a message to a process whose
address is unknown:
Sender: %s
From node: %s
Recipient: %s
On node: %s
The message could not be delivered, and we are aborting.
#
[failed-daemon-launch]
ORTE was unable to reliably start one or more daemons.
This usually is caused by:
* not finding the required libraries and/or binaries on
one or more nodes. Please check your PATH and LD_LIBRARY_PATH
settings, or configure OMPI with --enable-orterun-prefix-by-default
* lack of authority to execute on one or more specified nodes.
Please verify your allocation and authorities.
* the inability to write startup files into /tmp (--tmpdir/orte_tmpdir_base).
Please check with your sys admin to determine the correct location to use.
* compilation of the orted with dynamic libraries when static are required
(e.g., on Cray). Please check your configure cmd line and consider using
one of the contrib/platform definitions for your system type.
* an inability to create a connection back to mpirun due to a
lack of common network interfaces and/or no route found between
them. Please check network connectivity (including firewalls
and network routing requirements).
#
[failed-daemon]
An ORTE daemon has unexpectedly failed after launch and before
communicating back to mpirun. This could be caused by a number
of factors, including an inability to create a connection back
to mpirun due to a lack of common network interfaces and/or no
route found between them. Please check network connectivity
(including firewalls and network routing requirements).
2015-05-23 03:29:06 +03:00
#
[node-died]
ORTE has lost communication with a remote daemon.
2015-05-23 03:29:06 +03:00
HNP daemon : %s on node %s
Remote daemon: %s on node %s
2015-05-23 03:29:06 +03:00
This is usually due to either a failure of the TCP network
connection to the node, or possibly an internal failure of
the daemon itself. We cannot recover from this failure, and
therefore will terminate the job.
#
[no-path]
ORTE does not know how to route a message to the specified daemon
located on the indicated node:
my node: %s
target node: %s
This is usually an internal programming error that should be
reported to the developers. In the meantime, a workaround may
be to set the MCA param routed=direct on the command line or
in your environment. We apologize for the problem.
#
[no-connect]
ORTE is unable to establish a communication connection to the
specified daemon located on the indicated node:
my node: %s
target node: %s
This is usually due to a lack of common network interfaces and/or
no route found between them. Please check network connectivity (including
firewalls and network routing requirements). If these look okay,
then it could be an internal programming error that should be
reported to the developers. In the meantime, a workaround may
be to set the MCA param routed=direct on the command line or
in your environment.
#
[simple-message]
An internal error has occurred in ORTE:
%s
This is something that should be reported to the developers.
#
[normal-termination-but]